Receive Multi Coupler Units

For use in receive distribution systems, where low noise and high dynamic range
are important for distributing weak and strong signal
from one antenna system to many receivers.
Short Wave band coverage 100 KHz – 50 MHz
Burnout protected - Low noise amplifier
High dynamic range - High Isolation


For Receive Multi Coupler Unit
High Performance Shortwave
|
Model No.: |
6015 |
|
Number of outputs: |
4 |
|
Frequency range: |
0.1 - 50 MHz |
|
Gain setting: |
+1 dB |
|
Amplitude flatness: |
±1dB |
|
Noise figure : |
5dB |
|
Output intercept point -2nd order: |
+39dBm |
|
Output intercept point -3rd order: |
+29dBm |
|
Output for rated OIPs: |
+5dBm |
|
SWR input/output (50 W): |
<1.5:1 |
|
Isolation -Output to input: -Output to output: |
>35dB >25dB |
|
Maximum input signal -CW: -Pulse: |
2Watt 10Watts @t < 10seconds |
|
Power Supply: -AC power: -Fall back supply: |
230V±10% @50 - 60 Hz 12VDC (Isolated) |
|
Max power consumption: -AC power -DC power |
15Watts 25Watts |
|
Connectors: -RF input/output -Power AC -Power DC |
N,BNC,TNC or UHF sockets IEC plug Screw Terminal Block |
|
Dimensions: -With: -Depth: -Height: |
483mm (19”) 275mm (10.8”) 44mm (1.75”), 1unit |
|
Temperature -Operating -Storage |
0 to 70°C -20 to 90°C |
Data by March 2004
Comm-connect reserve the rights to amend prices and specifications without prior notice
Datasheet
Download this datasheet