Receive Multi Coupler Units

 

 

 

For use in receive distribution systems, where low noise and high dynamic range

are important for distributing weak and strong signal

from one antenna system to many receivers.

 

 VHF/UHF band coverage 50MHz – 1000 MHz

 

Burnout protected - Low noise amplifier

 

High dynamic range - High Isolation

 Built in 12V no break

 

 

 

 

 

 

 

SPECIFICATIONS

 

For Receive Multi Coupler Unit

 

Model No.:

6014

Number of outputs:                               

16

Frequency range:

50 - 1000 MHz

Gain setting:

 -7 to +3 dB

Amplitude flatness:

±2dB

Noise figure   (@max gain setting):

7dB

Output intercept point -2nd order:

+29dBm

Output intercept point -3rd order:

+19dBm

Output for rated OIPs:

+5dBm

SWR input/output (50 W):

<2:1

Isolation                                -Output to input:

                                             -Output to output:

>25dB

>25dB

Maximum input signal          -CW:

                                             -Pulse:

0.5Watt

5Watts @t < 10seconds

Power Supply:                      -AC power:

                                             -Fall back supply:

230V±10%  @50 - 60 Hz

12VDC (Isolated)

Max power consumption:     -AC power

                                             -DC power

10Watts

20Watts

Connectors:                         -RF input/output

                                             -Power AC

                                             -Power DC

N,BNC,TNC or UHF sockets

IEC plug

Screw Terminal Block

Dimensions:                         -With:

                                             -Depth:

                                             -Height:

483mm (19”)

275mm (10.8”)

88mm (3.5”), 2unit

Temperature:                       -Operating

                                             -Storage

0 to 70°C

-20 to 90°C

Options:

 

 

 

Band Pass filter comm. Bands

110V±10%  @50 - 60 Hz

24 Volt Fall back supply

Output bypass relay

                                      Data changed March 2004

 

Comm-connect reserve the rights to amend prices and specifications without prior notice

 

 

Datasheet
 Download this datasheet


Return home

E-mail COMM-connect

Modified 19-11-2004