VHF Probe for

Broadcast RF Power Monitor

 

 

 

True RMS Probe.

 

VHF Band I, II and III

 

Multi carrier and any waveform detector

 

RMS, Average and Peak Sync modes

 

Frequency compensated for use with Directional Coupler  

 

 

 

 

 

 

SPECIFICATIONS

For Broadcast Power Monitor VHF Probe

Model No.:

3016/3014#02

  Frequency range: (Coupler dependent)

50 – 250 MHz

Coupling Flatness ,  from 6dB/octave

±0,25dB

SWR input (50 W):

<1.2:1

Absolute accuracy after offset adjustment:

±0,1dB (±2,5%)

True RMS Power range @ 100MHz:

-29dBm to +15dBm

Peak Power range:

+29dBm

Dynamic range:

>50dB

Power Supply:                     -DC power:

5V supplied from RF Power Monitor

Max power consumption:    -DC

24mA

EMI/RFI

EN55022 /B

Connectors:                        -RF input   

                                            -RF sensor output

“N” male

Lemo 5 pole female

Interface cable:

Connectors:                        -RF sensor

                                            -RF Power Meter

Standard 2 meters

Lemo 5 pole male

DB9 Female  

Dimensions                         -Length:

                                            -Width:

                                            -Height:

90mm

25,4mm  

25,4mm

Weight:

Approx. 120g

Temperature:                      -Operating

                                            -Storage

5 to 50°C

-20 to 80°C

 Colour:                                  -Standard

Aludine-gold

                                       21.10.2004

                                      

              

Comm-connect reserve the rights to amend prices and specifications without prior notice

 

 

Datasheet
 Download this datasheet


Return home

E-mail COMM-connect

Modified 19-11-2004