Broadcast RF Power Monitor

Digital RF Power Meter.
RMS, Average and Peak Sync modes
VHF Band I, II and III, UHF Band IV and V
Frequency compensated for use with Directional Coupler
Optional VSWR Calculator.
Optional Alarms on Forward power, Reflected power and VSWR.
Optional controller for external temperature, voltage, and current
Monitoring and limit checking.

SPECIFICATIONS
|
Model No.: |
3014 |
|
Frequency range: (Coupler dependent ) |
50 860 MHz |
|
Coupling Flatness , from 6dB/octave Probes 3015,3016 |
±0,2dB
|
|
Absolute accuracy after offset adjustment: |
±0,2dB (±4%) |
|
True RMS Power range: |
-34dBm to +10dBm |
|
Peak Power range: |
+24dBm |
|
Dynamic range: |
>50dB |
|
Power readout: Auto range 1KW 999KW |
1024 steps |
|
Coupler attenuation VHF @ 100MHz: |
43dB to 73dB |
|
Coupler attenuation UHF @ 500MHz: |
50dB to 80dB |
|
VSWR readout: |
1,00:1 9,99:1 |
|
Remote Temperature Sensing |
0 - 99șC |
|
Remote Voltage Sensing |
0 100V DC |
|
Remote Current Sensing |
0 3V DC (1024 bits) |
|
Relay Out/Digital Out: |
Open Collector 50V/0,5A |
|
Controller out for SNMP or dialup |
RS232 1200- 9600 Bps |
|
Power Supply: -AC power: |
90-264V @50 - 60 Hz |
|
Max power consumption: -AC |
10V/A |
|
EMI/RFI |
EN55022 /B |
|
Connectors: - RF sensors - Power AC in rear Options: - Analogue/digital - - RS232 |
DB9 Female IEC DB9 Female DB9 Male |
|
Dimensions: - Width: 19 unit - Depth: - Height: |
482.5 mm 180 mm 44 mm |
|
Dimensions: - Width: Stand alone unit - Depth: - Height: |
216 mm 180 mm 53 mm |
|
Weight: |
Approx. 1,8 kg |
|
Temperature: - Operating - Storage |
5 to 50°C -20 to 80°C |
|
Colour: - Standard |
Silver Anodised |
21.10.2004
Comm-connect reserve the rights to amend prices and specifications without prior notice